Mobile Gaseous Decontamination System
GDS Mobile
GDS Mobile
A field‑ready vapour‑phase hydrogen peroxide (VPHP) generator for room decontamination. It delivers an automated, dry cycle with intelligent sensors, integrated catalytic converter for fast aeration, optional dehumidifier, and laptop‑based control. Multiple units can be networked for larger spaces.
Key features
- Automated process control: hydrogen peroxide and water‑vapour sensors monitor and record conditions; feedback maintains a dry, non‑condensing cycle.
- Simple user interface: control software runs on a laptop for easy set‑points and live graphs.
- Built‑in aeration: integrated catalytic converter breaks down H2O2 to oxygen and water vapour at the end of the cycle.
- Scalable: network multiple generators and control them remotely to treat larger volumes.
- Optional dehumidifier: supports low‑humidity, efficient VPHP cycles.
Technical specifications
- Max enclosure volume (per unit): 100 m³
- H2O2 injection rate: up to 10.0 g/min
- Relative humidity (nominal): to ~80%
- Dimensions (H × W × D): 610 × 610 × 203 mm
- Weight: ~40 kg
- Controller/HMI: laptop (software installed on customer‑supplied laptop)
- Power: 120 V 15 A 50/60 Hz; 200 V 10 A 50/60 Hz; 240 V 10 A 50/60 Hz
- Consumable: hydrogen peroxide 35–59% (low preservatives)
- Model number: GD‑MBLE‑VPHP‑01UT
Applications
- Room decontamination/sterilisation in hospitals, laboratories and pharmaceutical facilities
- Field or temporary facilities (e.g., command posts, shelters)
- Networked multi‑room treatments with laptop control
Compliance & safety
Operated by trained personnel following site procedures for hydrogen peroxide handling, aeration and re‑entry. The dry VPHP process helps protect sensitive materials by minimising condensation.
System components
- GDS Mobile generator with integrated catalytic converter and sensor bundle
- Laptop‑based control software (laptop not included)
- Optional dehumidifier
Maintenance & support
Periodic sensor calibration per manufacturer guidance; inspect filters and seals. J3Seven provides selection advice, documentation and after‑sales support Australia‑wide.
FAQs
How large a space can one unit treat?
Up to about 100 m³ per generator under typical conditions.
What’s the injection rate?
Up to 10 g/min of hydrogen peroxide vapour.
Can I network units?
Yes—multiple generators can be networked and controlled via a laptop to treat larger areas.
Is the cycle “dry”?
Yes—the system maintains a dry, non‑condensing VPHP environment and uses a catalytic converter for aeration at the end of the cycle.
What are the size and weight?
Approx. 610 × 610 × 203 mm; ~40 kg.