Service Equipment Decontamination System

GDS‑SEDS

A mobile, field‑ready decontamination chamber that uses vapour‑phase hydrogen peroxide (VHP) and modified VHP (with ammonia) to inactivate biological and chemical agents on mission‑critical equipment. The 230 ft³ (≈ 6.5 m³) enclosure features dual doors for clean/dirty segregation, pre‑set automated cycles and simple, one‑button operation.

Key features

  • Bio & chem decon in one system: VHP for biologicals; ammonia‑activated mVHP for chemical agents.
  • Through‑flow safety: dual doors support loading on the “dirty” side and unloading on the “clean” side to reduce cross‑contamination.
  • Automated, sensor‑led cycles: integrated feedback maintains setpoints and runs the full cycle automatically.
  • Temperature control: adjustable from ambient up to 50 °C to suit the mission and load.
  • Flexible interior: adjustable shelving to accommodate oversized items.
  • Fast deployment: set up in minutes; designed for single‑operator use with pre‑set programs.

Technical specifications

  • Internal volume: 230 ft³ (≈ 6.5 m³)
  • Total shelf area: 200 ft² (≈ 18.6 m²)
  • Decon media: VHP and modified VHP (hydrogen peroxide vapour with ammonia)
  • Cycle control: automated, sensor‑feedback with one‑button start
  • Temperature setpoint: ambient to 50 °C
  • Enclosure: ruggedised chamber with clean/dirty dual doors
  • Model: GD‑SEDS‑VPHP‑SYS1
  • Consumables: hydrogen peroxide solution, ammonia and filters (kit)

Applications

  • Decontamination of sensitive and non‑sensitive equipment
  • Decon lines supporting forward operations and maintenance hubs
  • Pharmaceutical/lab assets, comms, PPE and tools (as procedures allow)

What’s in the system

  • GDS‑SEDS chamber with dual doors and adjustable shelving
  • GDS generator (VHP/mVHP) with integrated sensors and controls
  • Consumables kit (H2O2 solution, ammonia, filters)

Maintenance & support

Routine sensor calibration is typically annual; peristaltic pump tubing replacement is recommended about every six months. J3Seven provides installation advice, consumables and after‑sales support Australia‑wide.

FAQs

How does it handle both biological and chemical threats?
VHP rapidly inactivates biological agents; adding ammonia activates the vapour (mVHP) to address chemical agents.

How is cross‑contamination reduced?
A through‑flow layout with dual doors isolates “dirty” loading from “clean” unloading.

What’s the usable capacity?
The chamber volume is about 230 ft³ (≈ 6.5 m³) with ≈ 18.6 m² of shelf area and adjustable racks for larger items.

How quickly can it be deployed?
Set‑up takes minutes; select the pre‑set program and press start for an automated, sensor‑controlled cycle.

Get in Touch Today